1depth
| RWC2010C FW Release V1.074 04.JUN.2026 | |
|---|---|
|
|
|
RWC2010C FW Release V1.074 04.JUN.2026
Version 1.074 1. When MDI files contained private-use tags, the MDI frame length could exceed the maximum frame length defined in the DRM Spec. This has been resolved by increasing the RWC2010X frame length limit to accommodate MDI files that include private-use data.
Version 1.073 1. In the FM RDS EON test, the Target Channel's Program Type now automatically changes to match EON_PTY when EON_SWITCH is turned ON, and reverts to its original value when EON_SWITCH is turned OFF. 2. Previously, Group 14B was transmitted only 3 times when EON_SWITCH was turned ON, and not transmitted at all when turned OFF. In this version, Group 14B is now transmitted continuously while EON_SWITCH is ON, and when EON_SWITCH is turned OFF, it sets EON_TA to OFF and EON_PTY to 0 (default), then transmits Group 14B 5 times before stopping. |